Thermal Engineer, Rack Level
Quick Summary
About EtchedEtched is building hardware for frontier intelligence. We co-design chips, racks, software,
Responsibilities
~1 min read- →
Own thermal design and validation of the L11 rack system, including the rack-level liquid loop, manifolds, quick disconnects, and interfaces to facility cooling..
- →
Develop and document deployment, fill, and commissioning processes for liquid-cooled racks, from first fill and leak checks through bring-up at customer sites.
- →
Validate reference CDU systems. This includes writing and executing test plans in the lab and in the field, and qualifying CDU partners on thermal performance, reliability, and controls.
- →
Characterize rack-level thermal and hydraulic performance (flow distribution, pressure drop, supply and return temperatures) and use the results to drive design decisions.
- →
Define and validate cooling-loop control strategies and how they interact with datacenter facility control systems.
- →
Support GTM and customers as the technical point of contact on facility integration questions, such as facility water requirements, CDU selection and sizing, secondary loop design, and water quality.
- →
Partner with tray and module (L6–L10) thermal engineers so that server-level designs meet rack-level and facility constraints.
- →
Create and maintain rack thermal specifications, commissioning procedures, validation reports, and customer-facing facility requirements documents.
- →
Investigate and resolve thermal and fluid-related issues in the lab and in deployed systems.
5–10 years of experience in thermal or mechanical engineering with direct, hands-on CDU and datacenter liquid cooling experience.
Experience installing, commissioning, or validating liquid cooling systems at datacenter scale.
Experience with CDU validation and commissioning, including flow, pressure, temperature, and controls testing.
Strong working knowledge of datacenter cooling loops (facility water and technology cooling system / secondary loops) and the control systems that run them.
Comfort working directly with customers, facility teams, and suppliers to resolve integration issues.
A Bachelor’s degree in Mechanical Engineering, Thermal Engineering, or a related field.
Nice to Have
~1 min readExperience deploying rack-scale direct-to-chip liquid cooling for AI or HPC systems at a hyperscaler, server OEM, or CDU vendor.
Familiarity with industry guidelines for datacenter liquid cooling, such as OCP and ASHRAE TC 9.9.
Experience with 1D flow network or system-level thermal/hydraulic modeling tools (e.g., Flownex, MacroFlow).
Knowledge of coolant chemistry, filtration, leak detection, and fluid integrity testing.
What We Offer
~1 min readLocation & Eligibility
About this job
- Pay per year
- $200,000–$350,000 a year
- 307% above the $67,500 median for Other jobs on Jobera (119,193 salaries).
- Who can apply
- United States
- Posted
- Today
Listing Details
- Posted
- October 20, 2026
- First seen
- October 20, 2026
- Last seen
- October 20, 2026
Posting Health
- Days active
- 0
- Repost count
- 0
- Trust Level
- 76%
- Scored at
- October 20, 2026
Signal breakdown
Stay ahead of the market
Get the latest job openings, salary trends, and hiring insights delivered to your inbox every week.
No spam. Unsubscribe at any time.