Commissioning Engineering Leader-AI Data Centers
Quick Summary
Develop the owner's commissioning standard, including commissioning plans and IST protocols for each facility type (hub, satellite and spoke). Witness factory acceptance testing (FAT) of switchgear,
Our client is a developer and owner of AI data center infrastructure, building a national network of power-dense AI inference data centers with on-site battery energy storage.
The company is delivering this network in partnership with a leading hyperscale cloud platform, rolling out hub, satellite and spoke facilities across a large national real estate portfolio.
The organization offers experienced mission-critical professionals the opportunity to build core programs from the ground up during a period of significant growth.
About the Role
~1 min readOur client is seeking a Commissioning Engineering Leader to serve as the owner's technical authority for commissioning across its AI data center portfolio.
Reporting to the Chief Technology Officer, this leader will build the owner's commissioning program from the ground up and lead it on site, from factory acceptance testing through Commercial Operation Date (COD). The role requires 50–70% national travel.
The ideal candidate has signed off on Tier III or Tier IV data centers going live, has personally authored IST scripts, and wants to build a commissioning program rather than run someone else's.
Responsibilities
~1 min read- →Develop the owner's commissioning standard, including commissioning plans and IST protocols for each facility type (hub, satellite and spoke).
- →Witness factory acceptance testing (FAT) of switchgear, UPS, generators, chillers, CDUs and BESS before equipment ships.
- →Lead site acceptance testing (SAT) and integrated systems testing (IST), including power-on, redundancy and failure-mode testing of N+1/2N systems.
- →Oversee BMS/EPMS integration and testing.
- →Commission battery energy storage systems and direct liquid cooling (CDU / cold plate) systems.
- →Drive punch lists to closure and issue COD readiness certification for each facility.
- →Support Uptime Institute Tier Certification efforts.
- →Direct general contractors, MEP subcontractors, OEMs and third-party commissioning agents on site.
- →Travel 50–70% to active construction and commissioning sites nationally.
Requirements
~1 min read- Bachelor's degree in Electrical or Mechanical Engineering or a related field.
- 7+ years of data center commissioning experience.
- Has led at least one Tier III or Tier IV data center from SAT through IST to COD.
- Has written IST scripts and run integrated failure-mode testing, not only executed others' checklists.
- Hands-on experience with switchgear, UPS, generators, chilled water / precision cooling and BMS/EPMS.
- Mission-critical data center commissioning experience; commercial, office, healthcare or HVAC-only backgrounds will not be considered.
- Ability and willingness to travel 50–70% nationally.
- BESS commissioning experience (LFP batteries, inverters, protection relay testing).
- Liquid cooling, CDU or direct-to-chip commissioning experience.
- CxA, ASHRAE commissioning or NETA certification.
- Professional Engineer (PE) license.
- Uptime Institute Tier Certification experience (ATS or ATD).
What We Offer
~1 min readLocation & Eligibility
About this job
- Pay per year
- $165,000–$230,000 a year
- 86% above the $106,080 median for Data Center Technician jobs on Jobera (169 salaries).
- Who can apply
- United States
- Posted
- Today
Listing Details
- First seen
- October 15, 2026
- Last seen
- October 16, 2026
Posting Health
- Days active
- 0
- Repost count
- 0
- Trust Level
- 71%
- Scored at
- October 16, 2026
Signal breakdown
Similar Data Center Technician jobs
View all →Browse Similar Jobs
Stay ahead of the market
Get the latest job openings, salary trends, and hiring insights delivered to your inbox every week.
No spam. Unsubscribe at any time.